  • Seamless drip tape with drippers permanently fixed inside. Seamless construction improves ability to withstand pressure fluctuations.
  • Marked with two parallel yellow stripes ‘Twin- Line®’. Symbol of quality. It also helps to ensure upright positioning of the dripper.
  • Manufactured from special grade, virgin polymer ensuring close dimensional tolerance and higher strength even at lower wall thickness.
  • Manufactured with the most modern, state-of-the-art equipment. It’s computerized continuous online quality control ensures reliable quality and consistent performance.
  • Innovative cascade labyrinth. Its hydrodynamically designed tooth structure helps to create double flow regime viz. central curving flow and turbulent cyclone in the dripper. This helps in continuous flushing of particles.
  • Three dimensional filter inlet, unique filtration surface enable clog free operation even under high clog risk conditions.
  • Precision laser drilled outlet holes.
  • Extremely low manufacturing coefficient of variation, CVm ensures high field emission uniformity.
  • Available in 12, 16, 17, 19 & 25 mm nominal diameter as per metric standard. 5/8”, 7/8”, 9/8” and 1-3/8” nominal diameter as per US standard.
  • Available in three discharge rates of 0.9, 1.4 and 3.5 lph at nominal operating pressure of 0.7 kg/cm² as per metric standard. 0.23, 0.37 and 0.93 gph at nominal operating pressure of 10 psi as per US standard.
  • Available in wall thickness ranging from 6mil to 25mil (0.15mm to 0.63mm).
  • Available in standard dripper spacing of 15, 20, 30, 40, 50, 60, 75, 90 and 100 cm. Any other spacing and group spacings are available on demand.
  • Specially designed Tape Lock™ fittings are available. Please refer to ‘Poly Fittings & Accessories’ page.
  • Minimum 100 micron filtration recommended. However required filtration type and precision depends upon quality of source water.

Applications

  • Recommended for closely spaced seasonal row crops like sugarcane, cotton, chilly, potato, ground nut, onion, vegetables, oil seeds, banana, strawberry, floriculture, etc.
  • Suitable for surface and subsurface applications.

Coil Lengths

Emitter
Spacing
Nominal Diameter of 16 mm, 17 mm and 5/8"
6 mil 8 mil 10 mil 12 mil 15 mil 18 mil 20 mil 25 mil
cm inch m ft. m ft. m ft. m ft. m ft. m ft. m ft m ft.
15 6 2100 6888 2100 6888 2000 6560 1700 5576 1350 4428 1000 3280 900 2952 500 1640
20 8 2300 7544 2300 7544 2100 6888 1800 5904 1400 4592 1050 3444 950 3116 550 1804
25 10 2400 7872 2400 7872 2150 7052 1850 6068 1450 4756 1100 3608 1000 3280 600 1968
30+ 12+ 2700 8856 2500 8200 2250 7380 1900 6232 1500 4920 1150 3772 1000 3280 600 1968
15 6 1300 4264 1100 3608 800 2624 900 2552 750 2460 650 2132 600 1968 350 1148
20 8 1500 4920 1300 4264 1000 3280 1000 3280 800 2624 700 2296 650 2132 350 1148
25 10 1600 5248 1400 4592 1100 3608 1050 3444 850 2788 750 2460 700 2296 400 1312
30+ 12+ 1800 5904 1500 4920 1200 3936 1100 3608 900 2952 800 2624 700 2296 450 1476

Note: 1 mil = 1/1000th part of an inch = 0.0254 mm.
* Coil lengths are for coil size 560 x 280 mm (22” x 11”). Other coil sizes such as 350x160 mm (13.8” x 6.3”) and 560x160 mm (22” x 6.3”) are also available. Please contact for coil lengths of J- Turbo Cascade Mini 12, 19, 25 mm and 9/8”, 1–3/8”.


Technical Specifications for Emitter

Reference
Code
Emitter Discharge Emitter exponent Flow Coefficient Coeff. of mfgr. Variation
lph at 0.7 kg/cm² lph at 1.0 kg/cm² gph at 10 psi gph at 14 psi x k CVm
DMXXX09 0.90 1.10 0.23 0.29 0.46 0.80 4
DMXXX14 1.40 1.70 0.37 0.45 0.46 1.30 4.5
DMXXX35 3.50 4.0 0.93 1.06 0.46 4.00 2.0

Technical Specifications for Tubing - Metric

Nominal
Diameter
Wall
Thickness
Inside
Diameter
Outside
Diameter
Max.
Operating
Pressure
Max.Flushing
Pressure
mm mil mm mm mm kg/cm² kg/cm²
Jain TurboCascade™ 12 mm Nominal Diameter
12 6 0.15 11.8 12.1 1.1 1.7
12 8 0.20 11.8 12.2 1.5 2.3
12 10 0.25 11.8 12.3 1.8 2.7
12 12 0.30 11.8 12.4 2.2 3.3
12 15 0.38 11.8 12.6 2.7 4.1
12 18 0.45 11.8 12.7 3.3 5.0
12 20 0.50 11.8 12.8 3.6 5.4
12 25 0.63 11.8 13.1 4.5 6.8
Jain TurboCascade™ 16 mm Nominal Diameter
16 6 0.15 15.9 16.2 0.8 1.2
16 8 0.20 15.9 16.3 1.1 1.7
16 10 0.25 15.9 16.4 1.4 2.1
16 12 0.30 15.9 16.5 1.6 2.4
16 15 0.38 15.9 16.7 2.0 3.0
16 18 0.45 15.9 16.8 2.4 3.6
16 20 0.50 15.9 16.9 2.7 4.1
16 25 0.63 15.9 17.2 3.4 5.1
Jain TurboCascade™ 17 mm Nominal Diameter
17 6 0.15 16.1 16.4 0.8 1.2
17 8 0.20 16.1 16.5 1.1 1.7
17 10 0.25 16.1 16.6 1.4 2.1
17 12 0.30 16.1 16.7 1.6 2.4
17 15 0.38 16.1 16.9 2.0 3.0
17 18 0.45 16.1 17.0 2.4 3.6
17 20 0.50 16.1 17.1 2.7 4.1
17 25 0.63 16.1 17.4 3.4 5.1
Jain TurboCascade™ 19 mm Nominal Diameter
19 6 0.15 19.0 19.3 0.7 1.1
19 8 0.20 19.0 19.4 0.9 1.4
19 10 0.25 19.0 19.5 1.1 1.7
19 12 0.30 19.0 19.6 1.4 2.1
19 15 0.38 19.0 19.8 1.7 2.6
19 18 0.45 19.0 19.9 2.0 3.0
19 20 0.50 19.0 20.0 2.3 3.5
19 25 0.63 19.0 20.3 2.8 4.2
Jain TurboCascade™ 25 mm Nominal Diameter
25 6 0.15 25.0 25.3 0.5 0.8
25 8 0.20 25.0 25.4 0.7 1.1
25 10 0.25 25.0 25.5 0.9 1.4
25 12 0.30 25.0 25.6 1.1 1.7
25 15 0.38 25.0 25.8 1.3 2.0
25 18 0.45 25.0 25.9 1.6 2.4
25 20 0.50 25.0 26.0 1.8 2.7
25 25 0.63 25.0 26.3 2.2 3.3
Note : 1 mil = 1/1000th part of an inch = 0.0254 mm.

Technical Specifications for Tubing - US

Nominal
Diameter
Wall
Thickness
Inside
Diameter
Outside
Diameter
Max.
Operating
Pressure
Max.Flushing
Pressure
inch mil mm inch inch psi psi
Turbo Cascade™ - Thin Wall 5/8" Nominal Diameter
5/8 6 0.15 0.625 0.637 11 17
5/8 8 0.20 0.625 0.641 15 23
5/8 10 0.25 0.625 0.645 20 30
5/8 12 0.30 0.625 0.649 22 34
5/8 15 0.38 0.625 0.655 28 43
5/8 18 0.45 0.625 0.661 34 51
5/8 20 0.50 0.625 0.665 38 58
5/8 25 0.63 0.625 0.675 48 73
Turbo Cascade™ - Thin Wall 7/8 Nominal Diameter
7/8 6 0.15 0.875 0.887 8 13
7/8 8 0.20 0.875 0.891 11 17
7/8 10 0.25 0.875 0.895 14 21
7/8 12 0.30 0.875 0.899 17 26
7/8 15 0.38 0.875 0.905 21 32
7/8 18 0.45 0.875 0.911 25 38
7/8 20 0.50 0.875 0.915 28 43
7/8 25 0.63 0.875 0.925 34 51
Turbo Cascade™ - Thin Wall 9/8 Nominal Diameter
9/8 6 0.15 1.125 1.425 7 10
9/8 8 0.20 1.125 1.525 9 12
9/8 10 0.25 1.125 1.625 11 15
9/8 12 0.30 1.125 1.725 13 20
9/8 15 0.38 1.125 1.9 16 24
9/8 18 0.45 1.125 2.0 20 29
9/8 20 0.50 1.125 2.1 22 33
9/8 25 0.63 1.125 2.4 27 41
Turbo Cascade™ - Thin Wall 1-3/8 Nominal Diameter
1-3/8 6 0.15 1.375 1.675 5 9
1-3/8 8 0.20 1.375 1.775 7 11
1-3/8 10 0.25 1.375 1.875 8 13
1-3/8 12 0.30 1.375 1.975 10 15
1-3/8 15 0.38 1.375 2.10 12 19
1-3/8 18 0.45 1.375 2.30 15 23
1-3/8 20 0.50 1.375 2.40 17 26
1-3/8 25 0.63 1.375 2.60 21 32
Note : 1 mil = 1/1000th part of an inch = 0.0254 mm.

Coil Lengths

Emitter Spacing Nominal Diameter of 16 mm, 17 mm and 5/8"
6 mil 8 mil 10 mil 12 mil 15 mil 18 mil 20 mil 25 mil
cm inch m ft. m ft. m ft m ft m ft. m ft. m ft. m ft.
15 6 2100 6888 2100 6888 2000 6560 1700 5576 1350 4428 1000 3280 900 2952 500 1640
20 8 2300 7544 2300 7544 2100 6888 1800 5904 1400 4592 1050 3444 950 3116 550 1804
25 10 2400 7872 2400 7872 2150 7052 1850 6068 1450 4756 1100 3608 1000 3280 600 1968
30+ 12+ 2700 8856 2500 8200 2250 7380 1900 6232 1500 4920 1150 3772 1000 3280 600 1968
Nominal Diameter of 7/8"
15 6 1300 4264 1100 3608 800 2624 900 2552 750 2460 650 2132 600 1968 350 1148
20 8 1500 4920 1300 4264 1000 3280 1000 3280 800 2624 700 2296 650 2132 350 1148
25 10 1600 5248 1400 4592 1100 3608 1050 3444 850 2788 750 2460 700 2296 400 1312
30+ 12+ 1800 5904 1500 4920 1200 3936 1100 3608 900 2952 800 2624 700 2296 450 1476

Note: 1 mil = 1/1000th part of an inch = 0.0254 mm
* Coil lengths are for coil size 560 x 280 mm (22” x 11”). Other coil sizes such as 350x160 mm (13.8” x 6.3”) and 560x160 mm (22” x 6.3”) are also available.Please contact for coil lengths of Jain Turbo Slim 12, 19, 25 mm and 9/8”, 1–3/8”.


Performance Graph :

Ordering Specifications